We offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are:
 
 
Zoll PD1200
 
The ZOLL PD 1200, combining defibrillation, pacing, and monitoring, offers complete ACLS-response capabilities in a single, easy-to-use unit that is ideal for critical and specialitycare areas. It can be configured with the ZOLL "hands-off" Multi-Function Electrodes, with standard defibrillation paddles and pacing electrodes, and with internal defibrillation paddles and pacing electrodes. The ZOLL PD 1200 operates on both AC line and battery power and is completely compatible with all models in theZOLL cardiac resuscitation system.
 
Features
Innovative features  :
  • Large Monitor
  • Non-fade monitor.
  • ECG monitor.
  • Strip recorder.
  • AC power supply for stationary use.
 
SPECIFICATIONS
 
Pacemaker
Type: VVI demand; asynchronous (fixed rate)
when used without ECG leads.
Pulse Type: Rectilinear, constant current.
Pulse Duration: 40 milliseconds.
Pulse Amplitude: Variable to 140 mA.
Pacing Rate: Variable from 30 to 180 PPM.
Output Protection: Fully defibrillator-protected and isolated.
Pacer On: Message display on monitor.
 
Defibrillator
Waveform: Damped sinusoid.
Output Energy
Delivered: Selectable at 2, 3, 5, 7, 10, 20, 30, 50,100, 150, 200, 300, 360 joules.
Charge Time: Less than 10 seconds.
Delivered Energy
Display: CRT monitor displays delivered energy.
Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message
displayed on monitor. Marker on monitor and on recorder paper identifies R-wave.
Internal Paddles: Output limited to 50 joules when internal paddles are connected. Discharge from
paddles.
Charge Controls: Control on apex paddle and front panel.
Paddles: Standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles.
Defibrillation Electrodes: Specifically designed ZOLL Multi- Function Electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs.
Integral Defibrillator Tester: Integral circuitry allows complete test
of defibrillator charge and discharge without removing paddles from storage wells. Identical circuitry allows completetest of unit configured with multifunction cable.
Defib On: Message display on monitor.
Monitor and Display

Patient Connection: Via 3-lead ECG cable, paddles, and elec trodes. Selectable by front panel switch.

Input Protection: Fully defibrillator-protected. Special circuit prevents distortion of ECG by pacer pulse.

Bandwidth: .5 – 40 Hz (–3dB) standard.

Display Format: Nonfade, moving trace with freeze capability

Monitor On: Message display on monitor.

Screen Type: High-resolution CRT display.

Screen Size: 5 inches diagonally (108 mm x 85 mm viewing area).

Sweep Speed: 25 mm/sec.

Viewing Time: 4 seconds.

Heart Rate: Digital display on monitor 0 – 300 BPM.

Pacer Output Current: Digital display on monitor 0 –140 mA.

ECG Lead Selection: Display on monitor.

ECG Size: .5, 1, 2 cm/mV display on monitor.

Alarm On/Off Status: Display on monitor. User selectable
High (60 – 280 BPM)
Low (20 – 100 BPM).

ECG Lead Off: Message display on monitor.

Pacer Electrode Off: Message display on monitor.

Defibrillator Paddle Fault: Message display on monitor.

Defibrillator Electrode Fault: Message display on monitor.

Recorder Paper Out: Message display on monitor.

Low Battery Voltage: Message display on monitor.

 
 