Drager Savina

TECHNICAL DATA SAVINA

Ventilation modes  – IPPV (CMV), IPPVAssist (CMVAssist)
                               – SIMV, SIMVASB (SIMV/PS)
                               – CPAP, CPAPASB (CPAP/PS)
                               – BIPAP1), (PCV+) (optional), BIPAP1)ASB (PCV+/PS) (optional)

Enhancements – NIV – Non Invasive Ventilation with optimized alarm system and
                                     automatic leakagecompensation (optional)
                              – AutoFlow® – Automatic adaptation of the inspiratory flow in volume
                                 orientated ventilation modes (optional).
                               – LPO - Low Pressure Oxygen. Independant oxygen supply,
                                  e.g. with an O2 concentrator (optional)
                               – Graphic screen - Advanced ventilation monitoring (optional),

                              – Nurse call - Connection for transmitting alarm signals to a central

Patient type                         Adult, pediatric
Ventilation frequency         2 to 80 bpm
Inspiration time                   0.2 to10 s
Tidal volume                        0.05 to 2.0 L, BTPS2)
Inspiratory flow                   0 to180 L/min
Inspiratory pressure           0 to 99 mbar 3) (cmH2O)
PEEP/interm. PEEP             0 to 35 mbar (cmH2O)
Pressure support/ASB        0 to 35 mbar (cmH2O) (relative to PEEP)
Flow acceleration                5 to 200 mbar/s (cmH2O/s)
O2-concentration                21 to100 Vol. %
Trigger sensitivity                 1 to15 L/min

Measured Value Display
Airway pressure                             Peak pressure, plateau pressure, mean airway pressure,
measurements  PEEP                    0 -100 mbar (cmH2O)
Minute volume (MV)                      Total MV, spontaneous MV 0 to 99 L/min, BTPS
Tidal volume VT                             Inspiratory VT, expiratory VT 0 to 3999 mL, BTPS
Breathing frequency                     Total and spontaneous breathing frequency, 0 -150 bpm
Inspiratory O2-concentration      21 to100 Vol. %
Breathing gas temperature        18 to 48 °C (sensor optional)
Curve displays                             Airway pressure / time, flow / time

Ventilation ratio (I:E)                   150:1 to 1:150

Alarms
Airway pressures                                          high / low
Expiratory minute volume                            high / low
Tidal volume                                                  high / low
Apnea-alarm time                                          15 to 60 sec
Spontaneous breathing frequency               high
Inspiratory O2-concentration                       high / low
Inspiratory breathing gas temperature         high
Performance data
Maximum flow for pressure assist/spontaneous breathing                           180 L/min
Valve response time T0…90                                                                           ≤ 5 ms
Control principle                                                                   time-cycled, volume-constant, pressure-   
                                                                                             controlled
Safety valve opening pressure                                            100 mbar (cmH2O)
Emergency valve                                                                 automatically enables spontaneous 
                                                                                              breathing with filtered ambientair if air
                                                                                              O2and O2 supply should fail.   

Automatic gas switch-over function if supply fails

Output for pneumatic medicament nebulizer                        synchronized with inspiration

Operating data
Main power connection                                  100 V to 240 V, 50/60 Hz AC, 10 to 36 V DC
Typical power consumption                           100 W
Internal battery                                               approx. 60 min (optional extension up to 7 h)
Digital machine outputs
Digital output and input via an RS 232 C interface,
Dräger Medibus standard
Gas supply

Air                                                              Turbine technology
O2 gas supply                                           3 bar (39 psi) to 10 % up to 6 bar (87 psi).
Dimensions and weights
Dimensions W x H x D (without trolley)             380 x 383 x 358 mm (15.0 x 156.1 x 14.1 inches)
Weight (basic device)                                       approx. 24 kg (53 lbs.)
Diagonal screen size                                         6.1" TFT color screen
1) BIPAP – Trademark used under licence
2) BTPS – Body Temperature Pressure Saturated. Measured values relating to the conditions of the patient lung, Body temperature 37 °C, steam-saturated gas,
ambient pressure.

3) 1 mbar = 100 Pa, AutoFlow®, Trademark by Dräge