Left Right
Follow Us
Home Line About Us Line Products Line Rental Line Line Services Line New Arrivals Line Enquiry Line Contact Us
Follow Us PRODUCTS >>CMS 9000 MULTIPARA MONITORS
CATEGORIES
 
We offer in cms 9000 model are known for their wide functionalities. These are used to report respiration, SPO2, ECG, Temperature, RESP,monitor, essential measurement parameters such as SpO2, TEMP, ECG, PR/HR, RESP and NIBP. These monitors are designed by latest digital technology which gives excellent accuracy.
   
Multipara Monitors
CMS 9000 Multipara Monitor
 

We have with us CMS 9000 Multipara Monitors that are designed using latest technology and as per the international standards. Procured from our reliable vendors, these monitors are compact in size and are easily portable. These monitors are incorporated with adjustable audible and visual alarm and other safety features. Further, our monitors are available in different specifications and at industry leading prices.

 
Features
Some features of the products are as follows :

- Color TFT Screen, waveform up to 8 channels
- Light and portable with build-in rechargeable battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
- 72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
- Built-in recorder(option)
- All-round monitor of adult, pediatric and neonatal.
- Electrosurgical unit and defibrillation protected
- Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
- Option parameters: EtCO2, CO, IBP, Thermal Printer

 
ECG :
- 5-lead or 3-lead selectable
- Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
- Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
- Gain selection: 12.5mm/s, 25mm/s, 50mm/s
- Accuracy: ± 1bpm or ± 1%, whichever is greater
- Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal: 1mV± 5%
- Operation modes: Diagnostic, Monitor, Surgery
- Alarm range: Adult: 15-300bpm
- Pediatric/Neonatal: 15-350bpm
- Alarm range: -2.0mV~2.0mV
- S-T detection: YES, Arrhythmia analysis: YES
- Alarm: YES, audible and visual alarm, alarm events recallable
 
NIBP 
- Method: Oscillometry
- Operation modes: Manual/Automatic/STAT
- Measurement unit: MmHg/KPa selectable
- Measurement types: Systolic, Diastolic, Mean
- Measurement range: Adult: 10-270mmHg
- Over-pressure protection: YES
- Resolution: 1mmHg
- Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm: Systolic, Diastolic, Mean
 
SpO2 
- Measurement range: 0-100%
- Accuracy: ± 2digit (70~100%);
- 0~69% unspecified
- Alarm range: 0-100%
 
Respiration
- Method: RA-LL impedance
- Pediatric/Neonatal: 6-150rpm
- Alarm range: Adult: 6-120rpm
- Pediatric/Neonatal: 6-150rpm
- Apnea alarm: YES
 
Temperature
- Resolution: 0.1
- Channel: Dual-channel
- Alarm range: 0-50
 
Option:
 
EtCO2
- Measurement Mode: Side-stream or mainstream
- Measurement range: EtCO2: 0-99mmHg
- Accuracy: CO2 concentration
- Apnea alarm: YES
 
CO
- Method: Thermo-dilution
- Measurement range: CO: 0.1-20 lit. /min.
 
IBP
- Channel: 2 channels
- Pressure transducer: Sensitivity: 5( mV/V/mmHg)
- Transducer sites: ART, PA, CVP, RAP, LAP, ICP
- Alarm range: -10~300mmHg
 
Online Order
      Copyright (@) 2011 Meditech Electronics Site Counter