Follow Us PRODUCTS >> CMS 8000 MULTIPARA MONITORS
CATEGORIES
 
We offer cms 8000 model are known for their wide functionalities. These are used to report respiration, SPO2, ECG, Temperature, RESP,monitor, essential measurement parameters such as SpO2, TEMP, ECG, PR/HR, RESP and NIBP. These monitors are designed by latest digital technology which gives excellent accuracy.
   
Multipara Monitors
CMS 8000 Multipara Monitor
 

We have with us CMS 8000 Multipara Monitors that are designed using latest technology and as per the international standards. Procured from our reliable vendors, these monitors are compact in size and are easily portable. These monitors are incorporated with adjustable audible and visual alarm and other safety features. Further, our monitors are available in different specifications and at industry leading prices.

 
Features
Technical Specifications :
  • Display:High 12.1″color TFT display 
  • Safety: IEC60601 (GB9706
  • Dimensions: 340mm(W)x270m(H)215mm(D)
  • Power Supply: 90-280V AC 50Hz/60Hz
  • Alarms Indication: Visual and audible alarm
  • 1000 groups of alarms events review
  • Application: Adult, pediatric and neonate
 
NIBP:
*Method: Oscillometry
* Modes: Manual/Auto/Comtinuous
* Auto measure time: Adjustable
* Measurement rang: 10-270mmHg
 
ECG:
*Lead mode: 3-lead or 5-lead
*Lead selection: I; II; III; AvR; AvL; AvF; V
* Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal: 15-300bpm
* ECG waveform: 2 channals
* Accuracy: ± 1 bpm or ± 1%
*S-T segment detection Measurement rang: -0.2mv~2.0mv
* Alarm: Yes, audible and visual alarm, alarm events review
*High resolution 12.1"color TFT display
* Lightweight, compact and portable
*ECG, APO2, NIBP, RESP, 2-TEMP, PR
*Optional: 2-IBP, ETCO2, And thermal printer
* Bulit-in rechargeable lithium battery
*ECG waveforms of 7-leads display on the same screen
*72-hours graphic and tabular trends of all parameters
* 72 alarm events of all parameters recall
*32 seconds full-disclosure waveform review
*500 NIBP measurement date can be storage and recall
*Date and waveforms color be adjustable
*Arrhythmia analysis and S-T segment analysis
*Suitable for adult, pediatric and neonatal patient
 
SPO2(Pulse Oximetry) :
*Measurement range: 0-100%
*Accyracy: 70-100%, ± 2% 0-69%, upspecified
Pulse rate
*Range: 20-254bpm
*Accuracy: ± 3bpm
 
Respiration
*Method: RA-LL impedance
* Range: Adult: 0-120rpm; Pediatric/neonatal: 0-150rpm
*Apnca alarmYes
 
Temperature
* Range: 0-50
*Apnca: 0.1
*Channal: Dual-Channal
 
Online Order
      Copyright (@) 2011 Meditech Electronics Site Counter